Tools

Engineering tools that make the spec easier.

Quick calculators our team reaches for every day: valve sizing, line velocity, unit conversions. Free to use; when you're ready, we'll help turn the numbers into the right product.

Liquid valve Cv

Required flow coefficient for a liquid control valve
GPM
psi
required Cv
Cv = Q √(SG/ΔP), for turbulent, non-choked liquid flow. For flashing, cavitating, or compressible service, confirm with the manufacturer's sizing.

Pipe velocity

Liquid velocity in a round pipe
GPM
in
ft/s
v = 0.4085 × Q/d². (2.067 in = Sch 40 2″ ID.) Keep liquids ~3–10 ft/s to limit erosion and water hammer.

Pressure converter

Convert between common pressure units

Temperature converter

°F · °C · K

Flow converter

Volumetric flow units

Estimates for convenience: they don't replace manufacturer sizing software or a stamped design. Working a specific application? Talk to a Rust engineer.

We keep this simple. Essential cookies keep the site working. We'd also like to count which pages and tools get used, so we build the ones that help you. Nothing is switched on until you say so, and we never sell your information. What we store.